Falcon · PLC bridge

No PLC code changes.
No HMI replacement.
Your line goes online.

Falcon installs physically between the HMI and the PLC. It passes the original serial traffic straight through while decoding every frame into usable field data. Nothing in the existing system changes — and the valuable control data trapped inside your PLC is visible immediately.

0 lines
of PLC code touched
60 min
to an AI-built remote HMI
RS-232/422/485
primary interfaces
topology / live
Remote HMI / Dashboard SCADA · WEB · MOBILE TCP / MQTT HMI EXISTING PANEL RS-232 / 422 / 485 FALCON ▸ PASS-THROUGH ▸ FRAME DECODE ▸ TAG MAPPING ▸ UPLINK QUEUE DIN RAIL · 24 VDC MODBUS RTU I/O PLC UNCHANGED PROGRAM FIELD LAYER · SERIAL ETHERNET MODEL · IN DEVELOPMENT
the problem

Your line's data is trapped in one serial cable.

The HMI can see it. The office cannot. Reports, remote monitoring, an MES connection — each one usually means touching PLC code, replacing the whole HMI, or pulling new network cable. Every option means downtime and risk.

Nobody knows the comms settings

The vendor is gone, the manual is lost, the engineer left. Baud rate, parity and slave ID become guesswork — one slow attempt at a time.

Nobody wants to touch a running system

Any PLC change means re-validation, downtime and liability. The HMI project file is a decade old and the source is nowhere to be found.

Remote monitoring costs too much to build

Tag lists, comms code, screen design — a remote HMI runs into weeks of engineering. Small projects never clear the bar.

the approach

One device. Three problems solved at once.

visible data

Every frame is decoded,
not just forwarded.

The Falcon is not a dumb cable. It understands field protocols such as Modbus RTU — function codes, address ranges, CRC validity, exception responses — so you can see what the line is saying the moment it is wired in.

  • — Live master/slave direction, station ID and function code
  • — CRC errors, timeouts and exception codes classified and counted
  • — Register-to-tag mapping with scaling and engineering units
  • — Buffered uplink queue: nothing is lost while the link is down
serial monitor / com3 · 38400 8E1
plant / operations

See it first. Improve it after.

Digitalisation does not have to start with a rebuild. Fit a Falcon to one critical machine and you have utilisation, output and fault counts the same day. Prove the value, then replicate.

system integrators

Turn a two-week quote into a one-day one.

Comms discovery, tag lists and a prototype screen used to take a week or two. With the Falcon and the AI workflow, you leave the first site visit with a demo that actually runs.

next step

Put one on a machine and see.

Tell us your equipment models and comms interface. We will assess feasibility and advise on a trial and rollout.